Your first winter with a heat pump may bring longer heating periods, radiators that feel warm rather than hot, and occasional defrost cycles. These can be expected. Judge performance by whether your home stays comfortable, your hot water meets your needs, and the system operates without recurring faults.
Getting used to a heat pump is partly about understanding the equipment and partly about finding a routine that suits your home. You should not need to spend winter continually checking an app or changing settings. But knowing what to look for makes it easier to recognise an ordinary change in operation, make a sensible adjustment or explain a concern to the support team.
This guide is designed to be kept and returned to. Start with the essentials, then use the section that answers your question.
Use the instructions for your installed system. This guide covers general winter ownership of Aurora II space heating with a separate Fjord I or Fjord Pro hot-water cylinder. The linked controller guides cover only the models and controllers identified beside each download. Do not assume they apply to Aurora III or another controller. Match the equipment nameplate and controller to your handover information. If the manual and handover advice differ, ask Adlår to resolve the difference before changing settings.
Start here: make a record of your system
Before changing anything, save the information you were given at handover. A photograph or screenshot of the original settings is particularly useful if you later need help.
Keep a record of | Why it helps |
Heat-pump and cylinder model names | Makes sure you use the correct instructions for heating and hot water. |
Heating mode and commissioned heat curve or target setting | Gives you a baseline to compare with later changes. |
Room controls and the areas they control | Helps distinguish a whole-house problem from a room or zone issue. |
Heating and hot-water schedules | Helps explain a cold morning or a gap in hot-water availability. |
Relevant app automations, including Smart Scenes | Shows which settings might change automatically. |
Support details and maintenance instructions | Makes the next step easy when you need assistance. |
If any of these are unclear, ask Adlår to explain them.
1. Your heating may feel different
Why are the radiators warm rather than hot?
Heat pumps often heat homes using lower-temperature water over longer periods. A radiator may feel less hot than it did with a boiler while still delivering enough heat to keep the room comfortable.
The useful question is: does this room reach and maintain the temperature you need? Touching a radiator gives you only a rough impression of its surface temperature. It does not tell you how much heat the room needs or whether that need is being met.
Radiator warmth can also change through the day. In milder weather, the system may need less heat. When it gets colder outside, the heating-water temperature may rise if weather compensation is active.
Does running for longer mean the heat pump is struggling?
Longer running is not, by itself, a fault. Keeping the system enabled does not mean its compressor consumes full power continuously. The equipment responds to demand, and its operation may include periods of reduced output or pauses.
For example, a home that stays comfortable through a cold day while the heat pump runs for long periods presents a different situation from a home that steadily gets colder despite the heating being enabled. The first observation may be consistent with normal operation; the second deserves investigation.
Avoid using runtime alone as a measure of efficiency. Comfort, weather, electricity use and system settings provide a more useful picture together.
How to check room comfort properly
Choose a few useful reference rooms: a main living room, a bedroom and any room that concerns you. If using a separate thermometer, keep it in a representative position away from radiators, direct sunlight, draughts and exterior surfaces that could distort the reading.
Record temperatures at similar times, such as when you get up and during the evening. Add a brief note about comfort and anything unusual: an open window, extra visitors, a strong wind or a schedule change.
A single reading after the front door has been open tells you less than a recurring pattern. Equally, do not ignore persistent underheating because you have been told heat pumps feel different. A properly functioning system should provide the comfort it was designed to deliver.
Why might one room behave differently?
Rooms lose heat at different rates. A corner bedroom with exposed walls may behave differently from a sheltered room downstairs. Radiator size, underfloor-heating design, water flow, draughts and room controls also affect comfort.
If one room is persistently cold while the rest of the house is comfortable, start by recording that local pattern. Raising the whole-house heating setting may make the other rooms too warm without resolving the underlying issue.
Related reading: Adlår’s post-installation FAQs include explanations of how heat-pump heating works, continuous operation and radiator temperatures.
2. Getting comfortable with your controls
Know which temperature you are looking at
Your system may show several temperatures. They describe different things and should not be compared as though they are interchangeable.
Reading | What it describes | How to use it |
Room temperature | The air temperature where a sensor is positioned | Helps you assess comfort in that location. |
Target heating-water temperature | The temperature the controller is aiming to supply | Helps explain the current heating setting. It is not a room-temperature target. |
Actual flow temperature | Water travelling towards the heating circuit | Helps the support team assess operation alongside other readings. |
Return temperature | Water coming back from the heating circuit | Provides further information about operation. It is not another room reading. |
Cylinder temperature | A sensor reading within the hot-water cylinder | Helps assess hot water operation but does not describe every part of the cylinder. |
For Aurora II or Fjord I, use the Display Operation guide only where the illustrated controller matches your installation. Fjord Pro has a separate user manual. Do not guess a reading’s meaning from its position on the screen. Display Operation — Aurora II 6, 10 and 14 kW; Fjord I 80, 120, 200 and 300 L
What does weather compensation do?
Weather compensation adjusts the heating-water temperature in response to the outdoor temperature. As conditions get colder, the home generally needs more heat. In milder weather, a lower water temperature may be sufficient.
A heat curve defines that relationship. Its purpose is to supply enough heat to maintain comfort without keeping the water unnecessarily hot throughout the season.
This explains why there is no single correct curve for every house. Insulation, radiator or underfloor-heating design, room temperatures and the building’s heat loss all influence the choice.
How do you know whether the curve needs reviewing?
Look for a pattern across rooms and weather conditions:
Most rooms are consistently too cool: the overall heating settings may need reviewing, alongside schedules and system operation.
Most rooms are consistently too warm: the system may be supplying more heat than needed.
Only one room struggles: investigate the room, its controls and heat delivery before changing the whole-house curve.
Comfort is good in mild weather but poor in colder weather: tell Adlår when the problem appears. That pattern is useful when reviewing the curve.
These observations guide a conversation; they do not identify a fault on their own. Follow the approved instructions for your controller. Do not assume that a larger curve number means hotter water; check the applicable curve chart or ask Adlår.
What does the room thermostat or sensor actually control?
Depending on the installation, a thermostat may control heating demand or an individual zone. A room sensor may provide information to an automation that adjusts heating settings. It may therefore behave differently from the on/off thermostat used with your previous boiler.
Ask which control you should use for an everyday comfort adjustment. Also ask whether other controls or automations can override it. A manual change that later disappears may be the result of a scheduled action rather than a controller fault.
Do not close large numbers of radiator valves or underfloor-heating circuits to experiment with the system. The installation needs appropriate water flow. Use room controls as explained at handover; changes to balancing or zone operation should follow Adlår’s advice.
Which app controls should you use day to day?
Begin with the app and device you were shown at handover. Check whether you are looking at the space-heating unit, the hot-water cylinder or a separate sensor.
Useful everyday tasks may include checking a setting, reviewing a schedule and seeing whether an automation is active. Installer parameters, factory resets and deleting device connections are not ordinary comfort adjustments.
Use the app and account confirmed at handover. Pairing instructions and available controls differ between models, so follow the guide supplied for your equipment. If the app name or instructions differ from what you were shown, contact Adlår before changing the setup. Phone Connection — Aurora II 6, 10 and 14 kW; Fjord I 80, 120, 200 and 300 L
3. Finding a routine that suits your home
Should you leave the heating on all the time?
Many heat-pump installations work well with long heating periods that maintain a comfortable baseline. Leaving the system enabled allows its controls to manage heat delivery; it does not require every component to run continuously.
Start with your commissioned routine. Repeatedly switching the heating off whenever a room feels warm, then turning it back on when the house feels cold, can make comfort less consistent and obscure how well the original settings work.
The right routine depends on your home and installation. A household occupied throughout the day has different needs from one regularly empty for long periods.
How should you approach overnight setbacks?
A setback reduces the intended heating level for a period rather than necessarily switching the system off. Whether it helps depends on the building, outdoor conditions, controls and the recovery needed afterwards.
A large overnight reduction can leave the house needing substantial reheating in the morning. Underfloor heating and heavier building fabric can respond gradually, so the effect may continue after you change the setting again.
There is no universal setback temperature or percentage saving to apply to every Adlår home. If you want a cooler sleeping environment or a different overnight routine, agree an approach that suits your system and test it consistently.
On the Aurora II controller described in the Display Operation guide, Eco/Night mode limits compressor and fan speed to reduce noise. It can also reduce available heating output. It is different from a room-temperature setback; ask Adlår to review it if comfort suffers during cold weather.
Build a routine in four steps
- Describe the need. For example: “The bedrooms feel too warm overnight, but the living room is comfortable during the day.”
- Check the existing routine. Look at schedules, room controls and relevant automations before adding another rule.
- Make one agreed change. Record the original setting and the time of the change.
- Review comfort and recovery. Did the bedroom improve? Is the home comfortable when you get up? Did the change affect other rooms?
Changing a curve, overnight schedule and several room controls together makes it difficult to identify which change helped.
Give an adjustment time to show its effect
For routine fine-tuning, assess the change over a meaningful period. The home’s fabric and heating emitters need time to respond; an immediate radiator-temperature check is not enough.
After a small heat-curve adjustment agreed with Adlår, allow the assessment period recommended for your installation before making another change. Compare room comfort and note the outdoor conditions during that period.
If heating or hot water is unavailable, a fault appears or temperatures are falling below a comfortable level, contact Adlår promptly. Do not wait for an assessment period to finish before reporting the problem.
What should you do before going away?
Check your model’s holiday or absence guidance before departure. Space heating and hot water may have separate settings.
- Confirm the intended heating arrangement for the empty home.
- If your cylinder has a holiday function, check how its absence period and return time are entered in the correct model manual.
- Keep the electrical supply available for the system’s protective functions, following your installation guidance.
- Keep the outdoor unit’s airflow and drainage areas clear.
- Know how to contact support if a problem appears while you are away.
Frost-protection features depend on the equipment and installation and cannot be assumed to protect every pipe in every circumstance. Electronic protection and active circulation require electricity. If a prolonged power cut occurs in freezing weather, contact Adlår for advice rather than attempting to drain or reconfigure the system yourself. Do not assume a fixed number of hours is safe.
For Fjord Pro hot-water controls, use its own manual. Its timer section distinguishes scheduling from the display (HMI) and the app: only one method is active at a time. Confirm which method is selected before editing schedules. Do not apply Fjord I timer or sensor instructions to Fjord Pro. Fjord Pro user manual — 160, 200 and 300 L
4. What changes when colder weather arrives?
Why does the heat pump use more electricity in winter?
Two things can happen together: the house loses more heat as the outdoor temperature falls, and the heat pump may need more electricity for each unit of heat delivered under colder operating conditions.
Longer running and higher consumption during a cold spell do not therefore prove that something is wrong. But comfort still matters. A cold-weather increase in consumption accompanied by rooms that remain comfortable needs interpreting differently from a sharp increase accompanied by falling room temperatures or recurring faults.
Wind, hot-water demand and recent setting changes can also affect the picture. Look at the combination rather than attributing everything to a single outdoor-temperature reading.
What is defrosting, and what might you notice?
In suitable weather conditions, frost can form on an air-source heat pump’s outdoor heat exchanger. The system can run an automatic defrost process to remove it.
During this process you may notice a change in sound, a pause or change in fan operation, water beneath the outdoor unit or a brief white plume. Heating behaviour can also temporarily change. The detail depends on the model and conditions.
There is no universal interval at which every heat pump should defrost. A damp, chilly day can produce a different pattern from a dry day at a lower temperature.
Observation | What to do |
A brief plume or water discharge during a defrost cycle | Observe whether the cycle finishes and normal operation resumes. |
Frost appears and is subsequently cleared | Keep airflow and drainage areas unobstructed and monitor comfort. |
Heavy ice persists or builds up, with poor heating or faults | Photograph it from a safe distance and contact Adlår. |
Water repeatedly freezes on a path or around access areas | Keep people clear of the slip hazard and report the drainage concern. |
Water appears to be leaking from pipework or an indoor component | Report the location; do not assume this is ordinary defrost water. |
Do not chip ice from the unit, pour hot water over it, open covers or attempt to force a defrost cycle. If you cannot tell whether an observation is expected, a photograph and the time it occurred are more useful than experimenting with service settings.
What should you do before a cold spell?
Check your usual comfort settings, make sure scheduled changes are intentional and remove loose leaves or snow around the unit where safe. Avoid last-minute changes to several controls simply because a colder forecast has arrived.
If the system already has an unresolved comfort problem, raise it before colder weather makes the pattern harder to manage.
5. Understanding your first winter’s electricity use
Start by knowing what the meter measures
A household electricity bill includes other appliances as well as heating. An app may show only one device, and a dedicated meter may cover the heat pump but not every associated component. Before comparing figures, establish what is included.
kW measures power at a moment; kWh measures energy used over time. A brief high-power reading does not tell you the total consumption for the day. The duration matters too.
A hot-water cylinder’s consumption may also sit separately from space heating. If your system has separate devices, do not assume a reading for one represents the total cost of heating and hot water.
A simple worked cost example
Suppose a meter covering the equipment you want to assess records 24 kWh over a day, and the electricity used costs 25p per kWh.
24 kWh × £0.25 = £6 in electricity unit charges.
These are invented figures to illustrate the calculation, not a typical Adlår consumption level, a current tariff or a prediction for your home. Standing charges are additional. With a time-of-use tariff, calculate consumption in each price period separately rather than applying one rate to all usage.
For a bill comparison, use actual billed rates and clearly state whether standing charges are included. That keeps a unit-cost calculation separate from the total amount you pay.
Compare with the heating fuel you have replaced
If you previously used gas, oil or another fuel for heating, some expenditure may now have moved to the electricity bill. An increase in electricity spending is therefore only part of the comparison.
Compare the combined relevant energy costs before and after the change, including heating and hot water. Note differences in weather, household occupancy, comfort temperatures and tariffs. Oil deliveries and gas billing periods may not line up neatly with a single month of electricity readings.
If an old fuel supply remains connected, check whether its standing charge still applies. Do not assume it has disappeared from household costs.
Keep a useful first-winter record
A simple weekly record is often more useful than repeatedly watching live power readings. Choose a consistent period and measurement source.
Record | Useful detail |
Electricity use | kWh over the period and exactly which equipment or meter it covers. |
Weather | Broad conditions, including cold spells or unusually windy periods. |
Comfort | Representative room readings and any recurring cold rooms. |
Hot-water demand | Guests, extra showers or other changes in usage. |
Settings | Any curve, schedule, boost or mode changes and when they occurred. |
You do not need a perfect scientific dataset. The aim is to distinguish “usage rose during a colder week” from “usage rose despite similar weather, unchanged routines and a new comfort problem”. Neither observation diagnoses a fault, but the second gives support a focused question to investigate.
What does COP tell you?
Coefficient of performance, or COP, compares heat delivered with electricity consumed over a defined operating period and measurement boundary.
For example, 9 kWh of measured heat delivered using 3 kWh of measured electricity gives a COP of 3 for that measurement. This is a mathematical illustration, not a guaranteed result or a target for every home.
Electricity readings alone cannot establish COP because you also need reliable heat-output information. A product test figure, a momentary reading and whole-season performance are different measures. Ask what a displayed efficiency figure includes before comparing it with a published specification.
When is a rise worth investigating?
Record an unexplained, sustained change, particularly if it coincides with poorer comfort, unexpected mode changes or frequent faults. A single busy day of hot-water use or a brief boost may explain a short-term rise.
Automatic hot-water hygiene cycles and supplementary heating can affect consumption. Keep the commissioned hygiene arrangements in place. If their operation seems excessive or unclear, ask Adlår to review them rather than disabling a protective function to reduce a graph’s peak.
6. Common concerns — and what to do next
Use this table to decide what information to gather. Carry out only the everyday checks explained for your installation.
Concern | Safe first checks | When to contact Adlår |
One room stays cold | Record its temperature; check its normal room control and whether furniture blocks the emitter. | The problem persists while other rooms are comfortable. |
Most or all rooms are cold | Check the intended heating mode, ordinary schedule and any displayed fault; note room temperatures. | Heating is unavailable, temperatures keep falling or the problem recurs. |
Hot water runs out too soon | Note usage, the cylinder’s normal schedule, displayed temperature and any fault. | Supply remains insufficient during normal use or fails to recover as expected. |
An unfamiliar noise appears | Note where it comes from, when it occurs and whether it coincides with defrost or other operation. | It is persistent, markedly different or accompanies vibration, poor heating or a fault. |
The app shows the device offline | Check home internet access and whether the physical controller shows normal operation. | Connection guidance does not resolve it, or operation is also affected. |
A fault code appears | Photograph the full code and identify which device displays it. | Follow the model-specific guidance; report persistent or recurring faults. |
Electricity use rises unexpectedly | Check the measurement period, weather, usage and recent settings. | The rise remains unexplained or coincides with a performance problem. |
If the whole house is cold
Check the controls you normally use: is heating intended to be enabled, is an absence setting still active, and has a schedule changed? Photograph the controller rather than relying on memory.
Tell support whether the system is producing any warmth, whether the problem started suddenly and whether an error is present. This helps distinguish an unexpected setting from a wider operational problem.
Do not repeatedly restart the system or change installer parameters to see what happens. A reset can obscure a recurring pattern without resolving its cause.
If only one room is cold
Check the ordinary room-temperature setting and remove anything obstructing the radiator or underfloor-heated area. Note whether the issue occurs all day, only in the morning or during colder weather.
Do not adjust balancing valves, manifold flow settings or zone actuators unless Adlår has given you instructions for that specific task. Those changes can affect other rooms and the system’s water flow.
If hot water is insufficient
Treat hot water as a separate question from room heating. Comfortable rooms do not prove that a separately controlled cylinder is operating as intended.
Record whether the problem is present before the first shower, only after several showers, at every hot tap or at one outlet. Note any change in household demand and whether the normal heating schedule has been interrupted.
A cylinder stores a finite amount of heated water and needs time to replenish it after use. Several showers close together may reveal a different issue from water that is already cool before normal demand begins.
Check the displayed cylinder reading using the correct model guide. Water is not necessarily the same temperature throughout the cylinder. In particular, do not assume Fjord I sensor explanations apply to Fjord Pro.
Use a one-off hot-water boost only where that function is documented for your cylinder and was explained at handover. A Fjord I boost button is not a Fjord Pro instruction. If you are unsure, contact Adlår. Do not alter safety valves, heating elements, mixing valves or hygiene settings. Tell support if extra heating is repeatedly needed to meet ordinary demand.
If the app is offline
An app connection problem does not, by itself, prove that heating has stopped. Check room comfort and the physical controller as well as the phone.
Confirm that the home internet is working and that you are using the correct app account and device. Follow the connection guide for your model. Avoid factory resets or deleting automations before you have recorded them and sought guidance.
If heating is also unavailable, report both problems so the investigation is not limited to Wi-Fi.
If an error appears
Send the complete code, including letters and numbers, and a photograph of the device displaying it. The same-looking code should not be assumed to have the same meaning on a heat pump and a cylinder.
The General & Fault Finding download is labelled for Aurora II and Fjord I, not Fjord Pro. It also contains service procedures and parameter changes. Use it to help identify information to report; do not follow repair instructions, open equipment or change service settings. Ask Adlår which customer action, if any, applies to your installation. General & Fault Finding — Aurora II 6, 10 and 14 kW; Fjord I 80, 120, 200 and 300 L
7. Small habits that help
Give the heating room to work
Keep radiators clear of large furniture and avoid heavy curtains covering them. Where practical, leave underfloor-heated areas able to release heat rather than covering large areas with thick insulating items.
If you use radiator fans or other supplied accessories, follow their instructions. Check that they have not been inadvertently switched off or obstructed before assuming the heat pump needs a higher setting.
Keep the outdoor unit’s surroundings clear
Remove loose leaves and snow around the unit where safe and accessible. Maintain the clear space established at installation. Do not store objects against it, cover it for winter or reach through grilles to clean internal parts.
Keep drainage areas visible and report recurring ice that affects safe access. Customer housekeeping does not replace professional inspection or maintenance.
Keep observation separate from repair
Useful customer action | Action to leave to Adlår or an appropriately qualified engineer |
Photograph a controller, gauge, leak or unusual ice. | Open equipment covers or inspect electrical components. |
Record temperatures and ordinary settings. | Alter installer or service parameters. |
Check familiar schedules and room controls. | Rebalance circuits or modify zone hardware. |
Follow a specific customer instruction supplied for your installation. | Work on refrigerant, cylinder safety devices or internal components. |
If you were shown a pressure gauge at handover, note an unexpected change and use the range given for your installation. Heating-system pressure and potable hot-water pressure are different. Repeated pressure loss needs investigating; do not treat repeated topping-up as routine care.
Follow the maintenance instructions and service arrangements supplied with your system. Report an emerging concern rather than waiting for a scheduled service if heating, hot water or safety is affected.
Use a simple change log
Before a routine adjustment, write down:
- What you want to improve.
- The original setting and the one change agreed.
- The date, time and broad weather conditions.
- What happened to comfort after allowing an appropriate assessment period.
For example: “The bedrooms felt too warm overnight. We changed only the agreed overnight setting. Morning comfort stayed acceptable, but the main bedroom was still too warm.” That is a useful result: it suggests the remaining question is local rather than a reason to keep lowering the whole house’s heating.
If a change makes comfort worse, use the agreed guidance for returning to the previous setting or contact support. Avoid stacking further adjustments onto an unexplained result.
8. When to contact us
Contact Adlår if heating or hot water is unavailable, a fault persists or keeps returning, a room remains consistently uncomfortable, or a change in operation cannot be explained by your normal settings and conditions.
You do not need to solve the problem before asking for help. A clear account of what you have noticed is enough to start.
What information helps the team investigate?
Include your address, the relevant equipment model and a short description of the effect on heating or hot water. Add the time the problem began, whether it is continuous or intermittent, and any recent setting changes.
Photographs of the controller and complete error messages help. So do representative room temperatures and a brief video of an unusual sound taken from a safe position. For consumption questions, include the period and what the meter or app figure covers.
A useful message might read:
“Since [date/time], [room or hot-water issue] has occurred [continuously/at these times]. The relevant model is [model]. The controller shows [setting/code], and the room temperature is [reading]. We last changed [setting] on [date], or have made no recent changes. Photographs are attached.”
Remote review may help the team understand settings and observations where the installation supports it. Some issues require an engineer’s visit or additional checks. The team will advise the appropriate next step.
For smoke, a burning smell, a serious leak or another immediate hazard, stop using the affected equipment and seek urgent assistance. Isolate it only if safe to do so; do not approach exposed electrical components or water near electrics. Contact the emergency services where there is immediate danger.
Contact Adlår on 01252 268 669 or info@adlar.co.uk. For any separate out-of-hours arrangement, use the details supplied at handover. Customer support
Keep these resources handy
- Mixed Aurora II and Fjord I topics; check the model named in each answer.
- Aurora II space heating with the illustrated controller; ask Adlår before following a control sequence that differs from your manual.
Performance Optimisation guide
- Aurora II space heating; observations can help a support discussion. Service parameters, pump adjustments and hydraulic changes are for Adlår or a qualified engineer.
- 160, 200 and 300 L hot-water cylinders; use the Pro display, timer and Wi-Fi sections.
- General help for Adlår customers; request a matching manual if your model is not listed.
Your first winter provides useful information about your home across different weather conditions. Keep the observations that matter, use the controls you have been shown and raise recurring concerns. The aim is a comfortable home with a routine you understand.